Maximum Controls EDI LMA-1800 Plug-In Vehicle Loop Detector – 10-Pin, 12/24V AC/DC


Price:
Sale price$134.99

Description

Maximum Controls EDI LMA-1800 Plug-In Vehicle Loop Detector – 10-Pin Inductive Loop Detector

The EDI LMA-1800 Plug-In Vehicle Loop Detector, offered through Maximum Controls, is a professional-grade, single-channel inductive vehicle detector designed for automatic gate operators, parking access systems, and commercial vehicle entry applications. Manufactured by Eberle Design (EDI), the LMA-1800 combines reliable vehicle detection, advanced loop diagnostics, adjustable sensitivity, and convenient plug-in installation in a compact 10-pin module.

Designed for compatible gate operator control boards equipped with a 10-pin loop detector receptacle, the LMA-1800 monitors an in-ground inductive loop and detects changes in inductance caused by vehicles entering or occupying the detection area.

The detector can be configured for common gate automation functions, including vehicle exit activation, center loop monitoring, and safety loop applications, depending on the connected controller and system design.

Unlike basic loop detectors that provide only a detection indication, the EDI LMA-1800 features a built-in DEFLECTOMETER™ display, adjustable sensitivity controls, loop frequency monitoring, programmable outputs, and nonvolatile loop fault memory.

These advanced diagnostic capabilities allow gate installers and service technicians to evaluate loop performance, identify wiring problems, and troubleshoot intermittent vehicle detection issues directly at the detector.

The LMA-1800 operates on 10–30V DC or 14–26V AC, supporting a variety of compatible low-voltage gate operator control systems.

With automatic loop tuning, four selectable frequency settings, ten sensitivity levels, and programmable fail-safe or fail-secure operation, the EDI LMA-1800 provides a versatile solution for residential, commercial, and industrial vehicle access installations.

Whether replacing a failed detector, servicing a Maximum Controls gate operator, or installing a new vehicle detection system, the EDI LMA-1800 delivers the diagnostic capabilities and reliable operation required by professional access control installers.

Key Features & Benefits

  • EDI LMA-1800 Vehicle Loop Detector: Professional-grade inductive loop detector manufactured by Eberle Design.

  • 10-Pin Plug-In Design: Fits compatible gate operator control boards equipped with the appropriate 10-pin detector connector.

  • Single-Channel Vehicle Detection: Monitors one inductive loop circuit for vehicle presence and detection events.

  • Dual Programmable Solid-State Outputs: Provides configurable detection and auxiliary output functions.

  • Built-In DEFLECTOMETER™ Display: Displays loop sensitivity response, frequency information, and diagnostic indications.

  • 10 Adjustable Sensitivity Levels: Allows technicians to optimize detection performance for the installation.

  • Four Selectable Frequency Settings: Helps reduce interference between nearby inductive loops.

  • Automatic Loop Tuning: Automatically adjusts to compatible loop and lead-in configurations.

  • Advanced Loop Fault Monitoring: Detects open circuits, short circuits, and sudden inductance changes exceeding 25%.

  • Nonvolatile Fault Memory: Retains previous loop fault information after power interruption.

  • Programmable Presence Detection: Supports normal and infinite presence settings.

  • Optional 2-Second Detection Delay: Provides configurable delayed vehicle detection.

  • Sensitivity Boost: Improves detection response for applications requiring additional sensitivity.

  • Fail-Safe or Fail-Secure Configuration: Supports selectable fault-response behavior.

  • Lightning & Transient Protection: Includes protected, transformer-isolated loop input circuitry.

  • Low-Voltage Operation: Supports 10–30V DC or 14–26V AC power.

  • Compact Plug-In Module: Simplifies replacement and maintenance in compatible control systems.

  • Wide Operating Temperature Range: Designed for demanding outdoor gate control environments when installed in an appropriate enclosure.

Technical Specifications

Specification Details
Product Manufacturer Eberle Design (EDI)
Offered Through Maximum Controls
Model Number LMA-1800
Product Type Plug-In Inductive Vehicle Loop Detector
Detection Channels Single Channel
Output Configuration Dual Programmable Solid-State Outputs
Connector 10-Pin Plug-In Molex-Type
DC Operating Voltage 10–30V DC
AC Operating Voltage 14–26V AC
Maximum Current Draw 50 mA
Adjustable Sensitivity 10 Levels (0–9)
Selectable Frequencies 4 Settings
Loop Frequency Range Approximately 13–150 kHz
Loop Inductance Range 20–2,500 µH
Minimum Loop Q Factor Greater Than 5
Loop Tuning Automatic
Loop Fault Monitoring Open, Shorted & Excessive Inductance Change
Loop Fault Memory Nonvolatile
Detection Delay Optional 2 Seconds
Presence Modes Normal & Infinite
Sensitivity Boost Selectable
Fault Configuration Fail-Safe / Fail-Secure
Output Type Open-Collector Solid-State
Maximum Output Rating 100 mA at 30V DC
Operating Temperature -30°F to +165°F (-34°C to +74°C)
Relative Humidity 0–95%
Dimensions 2.30" H × 2.75" W × 0.80" D
Approximate Weight 1.5 oz
Application Gate Operators, Parking Systems & Vehicle Access Controls

How the EDI LMA-1800 Vehicle Loop Detector Works

The EDI LMA-1800 operates by monitoring the inductance of a properly installed in-ground vehicle detection loop.

When a vehicle enters the loop's detection field, the metal mass of the vehicle changes the electrical characteristics of the loop circuit.

The detector identifies this change and activates its configured output, signaling the connected gate operator or access control system.

Depending on the controller and detector programming, this signal can be used to:

  • Open an automatic gate when a vehicle approaches an exit

  • Maintain a vehicle-presence signal while a vehicle occupies a detection area

  • Support gate control logic at commercial entrances

  • Provide vehicle detection for parking access systems

  • Coordinate with other compatible access control equipment

The LMA-1800 continuously monitors loop conditions and automatically compensates for environmental changes that could otherwise affect detection reliability.

Important: The detector requires a compatible inductive loop and appropriate controller connections. It does not detect vehicles without a properly installed loop circuit.

Built-In DEFLECTOMETER™ Diagnostics

One of the most valuable features of the EDI LMA-1800 is its integrated DEFLECTOMETER™ diagnostic display.

This front-panel display provides technicians with information about loop response and operating conditions.

The detector displays loop frequency during startup and provides a visual indication of detection sensitivity during normal operation.

This helps installers:

  • Evaluate loop response to passing vehicles

  • Adjust detection sensitivity

  • Identify interference between adjacent loops

  • Confirm detector operation

  • Diagnose inconsistent vehicle detection

  • Troubleshoot loop installation problems

By providing diagnostic information directly on the module, the LMA-1800 reduces the need for unnecessary component replacement during troubleshooting.

10 Adjustable Sensitivity Levels

The EDI LMA-1800 provides ten sensitivity settings, numbered 0 through 9, adjustable using front-panel controls.

Sensitivity adjustment allows the detector to be configured for different loop sizes, vehicle types, and installation conditions.

Proper sensitivity selection is important because settings that are too low may fail to detect certain vehicles, while excessively high settings can increase susceptibility to unwanted activation or interference.

The built-in DEFLECTOMETER™ display helps technicians evaluate the detection response and choose an appropriate setting.

For compatible Maximum Controls systems, installers should follow the gate operator manufacturer's sensitivity recommendations rather than automatically selecting the highest setting.

Four Selectable Loop Frequencies

The LMA-1800 includes four selectable operating frequency settings:

  • Low

  • Medium-Low

  • Medium-High

  • High

These settings help reduce interference when multiple inductive loops are installed near one another.

Adjacent loops operating at similar frequencies may interfere with each other, potentially causing false detections or unstable operation.

By selecting different frequencies, installers can improve loop separation and detection reliability.

The detector displays its operating frequency during startup, providing a useful diagnostic tool for installations with multiple loop detectors.

Advanced Loop Fault Monitoring

The EDI LMA-1800 continuously monitors the connected inductive loop for electrical faults and abnormal operating conditions.

It identifies three primary fault conditions:

Fault Indication Description
Open Loop F1 Broken or disconnected loop circuit
Shorted Loop F2 Short circuit in loop wiring
Excessive Inductance Change F3 Sudden inductance change exceeding 25%

Fault indications are provided through the detector's front-panel display and LED indicators.

These diagnostics help technicians identify damaged loop wiring, deteriorated connections, and other conditions that can affect gate operation.

Nonvolatile Loop Fault Memory

The LMA-1800 incorporates nonvolatile loop fault memory, allowing the detector to retain information about previous loop faults even after electrical power is removed.

This feature is particularly useful when troubleshooting intermittent problems.

For example, a loop may temporarily fail because of moisture intrusion, damaged wiring, or movement at a connection point.

By the time a technician arrives, the loop may appear to operate normally.

The LMA-1800's stored fault information can help identify whether an open circuit, short circuit, or excessive inductance change occurred previously.

The front-panel reset function allows technicians to clear stored indications after troubleshooting.

Programmable Detection & Output Functions

The EDI LMA-1800 provides configurable output behavior to support different vehicle detection applications.

Available functions include:

Presence Detection: Maintains a detection output while the detector recognizes a vehicle over the loop.

Normal or Infinite Presence: Allows the installer to select the appropriate presence-hold behavior.

Pulse on Entry: Configures an auxiliary output to provide a pulse when a vehicle enters the loop.

Pulse on Exit: Configures an auxiliary output to provide a pulse when a vehicle leaves the loop.

Loop Fault Output: Allows an output to indicate certain loop fault conditions.

2-Second Detection Delay: Provides an optional delay before detection activation.

Fail-Safe / Fail-Secure Selection: Allows the detector's response to certain loop fault conditions to be configured for the application.

The correct output mode depends on the connected controller and the intended loop function.

Important: Maximum Controls documentation for certain controllers specifically instructs installers not to select a pulsed output mode for loop detectors. Always follow the operator-specific wiring and programming instructions.

Maximum Controls Gate Operator Applications

Maximum Controls documents the use of EDI LMA-1800 plug-in loop detectors in its gate operator installation materials.

Depending on the operator model and control board, loop detector functions may include:

  • Exit loop detection

  • Center loop detection

  • Safety loop detection

  • Vehicle presence monitoring

  • Automatic gate activation

Maximum Controls control systems may provide dedicated plug-in detector positions or require an external loop detector adapter.

Compatibility must be verified by operator model and control board revision. A gate operator's support for vehicle loops does not necessarily mean it has a compatible 10-pin plug-in socket.

Additional Gate Operator Compatibility

EDI identifies the LMA-1800 as compatible with various gate operator control systems using supported 10-pin plug-in connections.

Manufacturer-listed applications include selected models from:

  • Chamberlain / Elite

  • All-O-Matic

  • Viking Access

  • Linear / OSCO

  • Advanced Access Automation

  • Intelligate Systems

  • SECOM

Compatibility depends on the specific controller and connector configuration.

Always verify the operator's loop detector requirements before installation.

Standard LMA-1800 vs. LMA-1800-LP

EDI manufactures two versions of this detector family.

LMA-1800 – Standard Model

  • 10–30V DC or 14–26V AC operation

  • Maximum current draw of approximately 50 mA

  • Intended for conventional powered access control installations

LMA-1800-LP – Low-Power Model

  • Designed for applications where reduced electrical consumption is important

  • Approximately 8–9 mA current consumption, depending on operating state

  • Suitable for compatible solar-powered and battery-powered systems

The standard LMA-1800 and low-power LMA-1800-LP should not be treated as identical products.

This listing is for the standard EDI LMA-1800, not the LMA-1800-LP low-power version.

Lightning Protection & Environmental Durability

The EDI LMA-1800 incorporates transformer-isolated loop circuitry and transient protection designed to improve reliability in electrically demanding installations.

The detector's printed circuit boards feature a protective conformal coating.

Its published operating temperature range extends from approximately -30°F to +165°F, making it suitable for a wide range of gate automation environments when installed within a suitable protected enclosure.

These features help support dependable operation at outdoor vehicle access systems, parking facilities, and commercial gate entrances.

Ideal Applications

The EDI LMA-1800 is suitable for:

  • Maximum Controls automatic gate operator systems

  • Commercial sliding gate operators

  • Residential and commercial swing gate operators

  • Automatic vehicle exit loops

  • Center and presence detection loops

  • Compatible safety loop control applications

  • Parking access control systems

  • Gated communities and HOA entrances

  • Industrial vehicle access points

  • Apartment and condominium entrances

  • Commercial parking facilities

  • Replacement of failed 10-pin plug-in loop detectors

Installation & Compatibility Considerations

The EDI LMA-1800 should be installed by qualified gate automation personnel.

Before installation:

  1. Confirm the controller supports the standard LMA-1800 detector.

  2. Verify the required operating voltage.

  3. Confirm the 10-pin connector and pin assignments.

  4. Inspect the inductive loop and lead-in wiring.

  5. Install the detector with power disconnected.

  6. Configure the appropriate frequency and sensitivity settings.

  7. Select the required output and presence modes.

  8. Test vehicle detection under actual operating conditions.

  9. Verify the complete gate control and safety system.

Safety Note: A vehicle loop detector is not a substitute for monitored entrapment protection devices required under UL 325. Required photoelectric sensors, contact edges, and other safety equipment must be installed separately according to the operator manufacturer's instructions.

Product Information & Ordering Notes

Brand / Distributor: Maximum Controls
Actual Manufacturer: Eberle Design (EDI)
Model: LMA-1800
Product: Plug-In Inductive Vehicle Loop Detector
Connector: 10-Pin
Power: 10–30V DC / 14–26V AC
Detection: Single Channel
Outputs: Dual Programmable Solid-State
Configuration: Standard-Power Model

Package Contents: One EDI LMA-1800 plug-in loop detector. In-ground vehicle detection loops, loop wire, external adapters, and other installation accessories are not included unless specifically identified.

Important: Confirm the exact controller compatibility and detector model before ordering.

Related Products

Recently viewed