{"product_id":"viking-dwlc10b-limit-cam-holder-f1-r6-t21-swing-gate-operators","title":"Viking Access Systems DWLC10B Limit Cam \u0026 Holder for F-1, R-6 \u0026 T-21 Swing Gate Operators","description":"\u003ch2\u003e\u003cspan\u003eViking Access Systems DWLC10B Limit Cam \u0026amp; Holder – F-1, R-6 \u0026amp; T-21 Swing Gate Operator Replacement Part\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eViking Access Systems DWLC10B Limit Cam \u0026amp; Holder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a genuine OEM replacement mechanical limit assembly designed for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eViking F-1, R-6, and T-21 automatic swing gate operators\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including applicable first-generation, revised, and solar-powered configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis replacement assembly is an essential component of the operator's mechanical travel limit system. The limit cams rotate with the operator's output shaft and activate the corresponding open and close limit switches, allowing the control board to recognize when the gate has reached its designated stopping positions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProperly functioning limit cams are critical for consistent automatic gate operation. Worn, cracked, loose, or slipping limit cams can interfere with travel limit detection, potentially causing inaccurate stopping positions or unreliable gate movement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DWLC10B provides a manufacturer-specified replacement solution for maintaining the mechanical limit system on compatible Viking swing gate operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhether servicing a residential driveway gate, replacing a damaged limit cam assembly, or restoring an earlier-generation Viking gate operator, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDWLC10B Limit Cam \u0026amp; Holder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps maintain proper gate travel adjustment and reliable mechanical limit activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGenuine Viking Access Systems Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – OEM limit cam and holder assembly for compatible Viking automatic swing gate operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMultiple Operator Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Designed for compatible Viking F-1, R-6, and T-21 swing gate operator families.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFirst-Generation Applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Listed for applicable Viking F-1 Gen 1 and T-21 Gen 1 configurations, subject to revision verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eR-6 Revision Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Supports applicable R-6 Revision 1 and Revision 2 operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eR-6 Solar Applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Compatible with applicable Viking R-6 solar-powered gate operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Travel Limit Control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Works with the operator's mechanical limit switches to identify fully open and fully closed gate positions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable Limit Cam Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Allows technicians to establish the proper gate stopping positions according to Viking adjustment procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOutput Shaft Integration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operates with the corresponding mechanical output shaft and limit switch system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFactory Replacement Assembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Replaces the corresponding DWLC10B limit cam and holder components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProfessional Gate Operator Maintenance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for qualified automatic gate installers and service technicians.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Viking DWLC10B Limit Cam \u0026amp; Holder is listed for the following Viking Access Systems swing gate operator families:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eViking F-1 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking F-1 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking F-1 Gen 1 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eViking R-6 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking R-6 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking R-6 Revision 1 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking R-6 Revision 2 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking R-6 Solar Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eViking T-21 Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking T-21 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking T-21 Gen 1 Swing Gate Operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant Compatibility Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Earlier Viking F-1, R-6, and T-21 operator manuals may identify the original limit cam and holder as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDWLC10\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while newer operator documentation identifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDWLC10B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlthough the DWLC10B is listed for these operator families, compatibility with earlier-generation assemblies should be verified before ordering. Compare the existing cam assembly, operator manufacturing revision, and applicable parts diagram.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Viking Access Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DWLC10B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Limit Cam \u0026amp; Holder Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eComponent Category:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical Travel Limit System Replacement Part\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatic Swing Gate Operator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Operator Families:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Viking F-1, R-6, and T-21\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFirst-Generation Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e F-1 Gen 1 and T-21 Gen 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eR-6 Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e R-6, Revision 1, Revision 2, and Solar\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical Activation of Open and Close Travel Limit Switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLimit System Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mechanical Cam-Actuated Limit Switch System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelated Limit Switch Part:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Viking DULS10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEarlier Limit Cam Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DWLC10 (verify replacement compatibility)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eR-6 Parts Diagram Reference:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Item #9 in newer R-6 documentation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eF-1 Parts Diagram Reference:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Item #14 in newer F-1 documentation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Location:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Output Shaft \/ Mechanical Limit Switch Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Genuine OEM Mechanical Replacement Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e(1) Viking Access Systems DWLC10B Limit Cam \u0026amp; Holder Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eMechanical limit switches, limit switch holders, wiring harnesses, output shafts, and other gate operator components are sold separately unless otherwise specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation and Application Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Viking DWLC10B Limit Cam \u0026amp; Holder operates within the mechanical travel limit system of compatible Viking automatic swing gate operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring normal operation, the operator's output shaft rotates as the motor and gearbox move the swing gate. The limit cams rotate with the shaft and engage the corresponding mechanical limit switches at the designated open and close stopping positions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese switches communicate with the operator's control board, allowing the gate operator to recognize when the intended travel limit has been reached.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA damaged or improperly adjusted limit cam assembly may contribute to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncorrect fully open or fully closed gate positions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInconsistent gate stopping locations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLimit cams slipping out of adjustment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailure to activate the mechanical limit switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExcessive gate travel beyond the intended stopping point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical interference or unreliable limit detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eWhen replacing the DWLC10B assembly, technicians should inspect the following related components:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOpen and close mechanical limit switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLimit switch holder and mounting hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLimit switch wiring harness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput shaft condition and alignment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLimit cam engagement and adjustment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGate arm linkage and mechanical travel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, both the open and close limit cams must be adjusted according to the applicable Viking Access Systems installation manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify correct switch activation, gate stopping positions, and all required safety functions before returning the gate operator to normal service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProfessional installation by a qualified gate automation technician is recommended.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Buy From GatePoint Solutions?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGatePoint Solutions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, we specialize in genuine automatic gate operator replacement parts, access control equipment, and professional gate automation components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOur selection of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eViking Access Systems replacement parts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports professional gate installers, service technicians, and property owners maintaining Viking F-1, R-6, T-21, and other automatic gate systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhether you need a Viking limit cam and holder, mechanical limit switches, limit switch bracket, output shaft, clutch assembly, gearbox, motor, or control board, GatePoint Solutions provides access to OEM components for automatic gate operator maintenance and repair.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eShop Viking Access Systems replacement parts at GatePoint Solutions for professional gate automation repair and maintenance solutions.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Ordering Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eVerify your Viking operator model, manufacturing generation, and existing limit cam assembly before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarlier operator revisions may use the DWLC10 configuration. Confirm that DWLC10B is appropriate for your specific operator before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DWLC10B includes the replacement limit cam and holder assembly only. Mechanical limit switches, wiring harnesses, and other related components are not included unless otherwise specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisconnect electrical and battery power, secure the gate against unexpected movement, and follow Viking Access Systems service instructions before performing repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, adjust and test the open and close travel limits and verify all required gate safety functions before returning the system to service.\u003c\/span\u003e\u003c\/p\u003e","brand":"Viking Access Systems","offers":[{"title":"Default Title","offer_id":46772538114223,"sku":"GPS-VK-DWLC10B","price":48.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/2394\/0015\/files\/Viking_Access_Systems_DWLC10B_Limit_Cam_Holder_for_F-1_R-6_T-21_Swing_Gate_Operators_GatePoint_Solutions.jpg?v=1794960674","url":"https:\/\/gatepointsolutions.com\/products\/viking-dwlc10b-limit-cam-holder-f1-r6-t21-swing-gate-operators","provider":"GatePoint Solutions","version":"1.0","type":"link"}