{"product_id":"maximum-controls-edi-lma-1800-plug-in-loop-detector","title":"Maximum Controls EDI LMA-1800 Plug-In Vehicle Loop Detector – 10-Pin, 12\/24V AC\/DC","description":"\u003ch1 data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eMaximum Controls EDI LMA-1800 Plug-In Vehicle Loop Detector – 10-Pin Inductive Loop Detector\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEDI LMA-1800 Plug-In Vehicle Loop Detector\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, offered through Maximum Controls, is a professional-grade, single-channel inductive vehicle detector designed for automatic gate operators, parking access systems, and commercial vehicle entry applications. Manufactured by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEberle Design (EDI)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the LMA-1800 combines reliable vehicle detection, advanced loop diagnostics, adjustable sensitivity, and convenient plug-in installation in a compact 10-pin module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatible gate operator control boards equipped with a 10-pin loop detector receptacle, the LMA-1800 monitors an in-ground inductive loop and detects changes in inductance caused by vehicles entering or occupying the detection area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe detector can be configured for common gate automation functions, including vehicle exit activation, center loop monitoring, and safety loop applications, depending on the connected controller and system design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike basic loop detectors that provide only a detection indication, the EDI LMA-1800 features a built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDEFLECTOMETER™ display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, adjustable sensitivity controls, loop frequency monitoring, programmable outputs, and nonvolatile loop fault memory.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese advanced diagnostic capabilities allow gate installers and service technicians to evaluate loop performance, identify wiring problems, and troubleshoot intermittent vehicle detection issues directly at the detector.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe LMA-1800 operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10–30V DC or 14–26V AC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting a variety of compatible low-voltage gate operator control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith automatic loop tuning, four selectable frequency settings, ten sensitivity levels, and programmable fail-safe or fail-secure operation, the EDI LMA-1800 provides a versatile solution for residential, commercial, and industrial vehicle access installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhether replacing a failed detector, servicing a Maximum Controls gate operator, or installing a new vehicle detection system, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEDI LMA-1800\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers the diagnostic capabilities and reliable operation required by professional access control installers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEDI LMA-1800 Vehicle Loop Detector:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Professional-grade inductive loop detector manufactured by Eberle Design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e10-Pin Plug-In Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fits compatible gate operator control boards equipped with the appropriate 10-pin detector connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Channel Vehicle Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monitors one inductive loop circuit for vehicle presence and detection events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDual Programmable Solid-State Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides configurable detection and auxiliary output functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuilt-In DEFLECTOMETER™ Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Displays loop sensitivity response, frequency information, and diagnostic indications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e10 Adjustable Sensitivity Levels:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows technicians to optimize detection performance for the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFour Selectable Frequency Settings:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps reduce interference between nearby inductive loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic Loop Tuning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically adjusts to compatible loop and lead-in configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdvanced Loop Fault Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detects open circuits, short circuits, and sudden inductance changes exceeding 25%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNonvolatile Fault Memory:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Retains previous loop fault information after power interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProgrammable Presence Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports normal and infinite presence settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOptional 2-Second Detection Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides configurable delayed vehicle detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSensitivity Boost:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Improves detection response for applications requiring additional sensitivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFail-Safe or Fail-Secure Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports selectable fault-response behavior.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLightning \u0026amp; Transient Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes protected, transformer-isolated loop input circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow-Voltage Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports 10–30V DC or 14–26V AC power.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompact Plug-In Module:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simplifies replacement and maintenance in compatible control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for demanding outdoor gate control environments when installed in an appropriate enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Manufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEberle Design (EDI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOffered Through\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLMA-1800\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-In Inductive Vehicle Loop Detector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDetection Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Programmable Solid-State Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10-Pin Plug-In Molex-Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC Operating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–30V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Operating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14–26V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Current Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Levels (0–9)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSelectable Frequencies\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Settings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Frequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 13–150 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Inductance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–2,500 µH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Loop Q Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater Than 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Tuning\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Fault Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen, Shorted \u0026amp; Excessive Inductance Change\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Fault Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNonvolatile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDetection Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional 2 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePresence Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNormal \u0026amp; Infinite\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity Boost\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSelectable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFault Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-Safe \/ Fail-Secure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-Collector Solid-State\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Output Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA at 30V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°F to +165°F (-34°C to +74°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–95%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.30\" H × 2.75\" W × 0.80\" D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 oz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGate Operators, Parking Systems \u0026amp; Vehicle Access Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eHow the EDI LMA-1800 Vehicle Loop Detector Works\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 operates by monitoring the inductance of a properly installed in-ground vehicle detection loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen a vehicle enters the loop's detection field, the metal mass of the vehicle changes the electrical characteristics of the loop circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe detector identifies this change and activates its configured output, signaling the connected gate operator or access control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on the controller and detector programming, this signal can be used to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOpen an automatic gate when a vehicle approaches an exit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain a vehicle-presence signal while a vehicle occupies a detection area\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupport gate control logic at commercial entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvide vehicle detection for parking access systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCoordinate with other compatible access control equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe LMA-1800 continuously monitors loop conditions and automatically compensates for environmental changes that could otherwise affect detection reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The detector requires a compatible inductive loop and appropriate controller connections. It does not detect vehicles without a properly installed loop circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt-In DEFLECTOMETER™ Diagnostics\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOne of the most valuable features of the EDI LMA-1800 is its integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDEFLECTOMETER™ diagnostic display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis front-panel display provides technicians with information about loop response and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe detector displays loop frequency during startup and provides a visual indication of detection sensitivity during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis helps installers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvaluate loop response to passing vehicles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjust detection sensitivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdentify interference between adjacent loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm detector operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnose inconsistent vehicle detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTroubleshoot loop installation problems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eBy providing diagnostic information directly on the module, the LMA-1800 reduces the need for unnecessary component replacement during troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e10 Adjustable Sensitivity Levels\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eten sensitivity settings, numbered 0 through 9\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, adjustable using front-panel controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSensitivity adjustment allows the detector to be configured for different loop sizes, vehicle types, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProper sensitivity selection is important because settings that are too low may fail to detect certain vehicles, while excessively high settings can increase susceptibility to unwanted activation or interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe built-in DEFLECTOMETER™ display helps technicians evaluate the detection response and choose an appropriate setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor compatible Maximum Controls systems, installers should follow the gate operator manufacturer's sensitivity recommendations rather than automatically selecting the highest setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFour Selectable Loop Frequencies\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe LMA-1800 includes four selectable operating frequency settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMedium-Low\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMedium-High\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese settings help reduce interference when multiple inductive loops are installed near one another.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdjacent loops operating at similar frequencies may interfere with each other, potentially causing false detections or unstable operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBy selecting different frequencies, installers can improve loop separation and detection reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe detector displays its operating frequency during startup, providing a useful diagnostic tool for installations with multiple loop detectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced Loop Fault Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 continuously monitors the connected inductive loop for electrical faults and abnormal operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt identifies three primary fault conditions:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFault\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIndication\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Loop\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBroken or disconnected loop circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShorted Loop\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort circuit in loop wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExcessive Inductance Change\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSudden inductance change exceeding 25%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eFault indications are provided through the detector's front-panel display and LED indicators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese diagnostics help technicians identify damaged loop wiring, deteriorated connections, and other conditions that can affect gate operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNonvolatile Loop Fault Memory\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe LMA-1800 incorporates \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enonvolatile loop fault memory\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the detector to retain information about previous loop faults even after electrical power is removed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis feature is particularly useful when troubleshooting intermittent problems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example, a loop may temporarily fail because of moisture intrusion, damaged wiring, or movement at a connection point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBy the time a technician arrives, the loop may appear to operate normally.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe LMA-1800's stored fault information can help identify whether an open circuit, short circuit, or excessive inductance change occurred previously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe front-panel reset function allows technicians to clear stored indications after troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProgrammable Detection \u0026amp; Output Functions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 provides configurable output behavior to support different vehicle detection applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable functions include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePresence Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Maintains a detection output while the detector recognizes a vehicle over the loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNormal or Infinite Presence:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the installer to select the appropriate presence-hold behavior.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePulse on Entry:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Configures an auxiliary output to provide a pulse when a vehicle enters the loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePulse on Exit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Configures an auxiliary output to provide a pulse when a vehicle leaves the loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLoop Fault Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows an output to indicate certain loop fault conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2-Second Detection Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides an optional delay before detection activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFail-Safe \/ Fail-Secure Selection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the detector's response to certain loop fault conditions to be configured for the application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe correct output mode depends on the connected controller and the intended loop function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Maximum Controls documentation for certain controllers specifically instructs installers not to select a pulsed output mode for loop detectors. Always follow the operator-specific wiring and programming instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMaximum Controls Gate Operator Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Controls documents the use of EDI LMA-1800 plug-in loop detectors in its gate operator installation materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on the operator model and control board, loop detector functions may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExit loop detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCenter loop detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety loop detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVehicle presence monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic gate activation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Controls control systems may provide dedicated plug-in detector positions or require an external loop detector adapter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility must be verified by operator model and control board revision.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A gate operator's support for vehicle loops does not necessarily mean it has a compatible 10-pin plug-in socket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdditional Gate Operator Compatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEDI identifies the LMA-1800 as compatible with various gate operator control systems using supported 10-pin plug-in connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer-listed applications include selected models from:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChamberlain \/ Elite\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll-O-Matic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eViking Access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinear \/ OSCO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdvanced Access Automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntelligate Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSECOM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility depends on the specific controller and connector configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify the operator's loop detector requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eStandard LMA-1800 vs. LMA-1800-LP\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEDI manufactures two versions of this detector family.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLMA-1800 – Standard Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10–30V DC or 14–26V AC operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum current draw of approximately 50 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntended for conventional powered access control installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLMA-1800-LP – Low-Power Model\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for applications where reduced electrical consumption is important\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApproximately 8–9 mA current consumption, depending on operating state\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for compatible solar-powered and battery-powered systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe standard LMA-1800 and low-power LMA-1800-LP should not be treated as identical products.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThis listing is for the standard EDI LMA-1800, not the LMA-1800-LP low-power version.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eLightning Protection \u0026amp; Environmental Durability\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 incorporates transformer-isolated loop circuitry and transient protection designed to improve reliability in electrically demanding installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe detector's printed circuit boards feature a protective conformal coating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts published operating temperature range extends from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-30°F to +165°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for a wide range of gate automation environments when installed within a suitable protected enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese features help support dependable operation at outdoor vehicle access systems, parking facilities, and commercial gate entrances.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Controls automatic gate operator systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial sliding gate operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResidential and commercial swing gate operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic vehicle exit loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCenter and presence detection loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible safety loop control applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eParking access control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGated communities and HOA entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial vehicle access points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApartment and condominium entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial parking facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement of failed 10-pin plug-in loop detectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation \u0026amp; Compatibility Considerations\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EDI LMA-1800 should be installed by qualified gate automation personnel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore installation:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the controller supports the standard LMA-1800 detector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify the required operating voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the 10-pin connector and pin assignments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect the inductive loop and lead-in wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the detector with power disconnected.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigure the appropriate frequency and sensitivity settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSelect the required output and presence modes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTest vehicle detection under actual operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify the complete gate control and safety system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSafety Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A vehicle loop detector is not a substitute for monitored entrapment protection devices required under UL 325. Required photoelectric sensors, contact edges, and other safety equipment must be installed separately according to the operator manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Information \u0026amp; Ordering Notes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand \/ Distributor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Maximum Controls\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eActual Manufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Eberle Design (EDI)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LMA-1800\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Plug-In Inductive Vehicle Loop Detector\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConnector:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10-Pin\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10–30V DC \/ 14–26V AC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDetection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single Channel\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOutputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual Programmable Solid-State\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standard-Power Model\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e One EDI LMA-1800 plug-in loop detector. In-ground vehicle detection loops, loop wire, external adapters, and other installation accessories are not included unless specifically identified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Confirm the exact controller compatibility and detector model before ordering.\u003c\/span\u003e\u003c\/p\u003e","brand":"Maximum Controls","offers":[{"title":"Default Title","offer_id":50715604648111,"sku":"GPS-MAX-PLUGINLOOPDETECTOR","price":134.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/2394\/0015\/files\/Maximum_Controls_EDI_LMA-1800_Plug-In_Vehicle_Loop_Detector_10-Pin_1224V_ACDC_GatePoint_Solutions.jpg?v=1792791506","url":"https:\/\/gatepointsolutions.com\/products\/maximum-controls-edi-lma-1800-plug-in-loop-detector","provider":"GatePoint Solutions","version":"1.0","type":"link"}